Installation
2.4 CONTROLLING THE SCANNER FROM THE POS SYSTEM
The Sirius S-7030 can be controlled from the POS system via the RS-232
interface or USB/COM Port Emulation. Control is achieved by transmitting the
following single byte commands to the scanner. In the Scantech default setting
the following commands are available (more details available upon request):
ASCII code Function Byte is also called:
05 Hex Power-up re-initialization ENQ or <Ctrl-E>
OE Hex Enable (cancels disable) Shift Out or <Ctrl-N>
OF Hex Disables the scanner Shift In or <Ctrl-O>
12 Hex Puts scanner into Sleep DC2 or <Ctrl-R>
14 Hex Wake (cancels sleep) DC4 or <Ctrl-T>
When the scanner is disabled, the motor of the scanner will stay on,
until the scanner goes into sleep mode.
2.5 STANDARD AVAILABLE INTERFACE CABLES
On the next pages you see the standard available interface cables with some
additional information.
Note that the power injector may be used to insert the DC power from the
optional external power supply. However if your POS/PC system provides
sufficient power directly via the data port, no external power supply is required.
A safety measure prevents from damage in case you connect a power supply
where it is not required (by disconnecting the power from the POS/PC system).
If you are using the Sirius with USB interface, no external power supply is
required at all.