92 Miscellaneous Parameters
8.3 CHARACTER DELETION
To setup the deletion of output characters:
1. Scan the programming code of the desired set.
2. Scan the programming code of the desired symbology.
3. Go to the decimal Value tables in Appendix A, scan programming
codes that represents the desired position to be deleted.
4. Scan the “Complete” programming code of “Character Position to be
Deleted”.
5. Go to the Decimal Value Tables in Appendix A, scan programming
codes that represents the number of characters to be deleted.
6. Scan the “Complete” programming code of “Number of Characters to
be deleted”.
Repeat the steps 1 – 6 to set additional deletion.
Example: Delete first 3 codes for Code EAN-13.
Start Configuration
1
st
Set
Code EAN-13
1st Digit – Delete From the 1
st
Digit
Complete
3 – Delete 3 Characters